Lotus LD4R 4-Inch Deep Regressed LED Downlight – 15W Open Plenum

Brand
Lotus LED Lights
SKU
LD4R-27K-4R-WR-WT
GTIN / UPC
736832281606
Product family
Regressed
Indicative Lotus availability: 1

Indicative figure for Lotus's warehouses (Vancouver and Ontario). It may not be current and is not guaranteed stock. Confirm project quantities and lead time.

SKU: LD4R-27K-4R-WR-WT
Regular price $83.16
Reflector and Trim Finish
Color Temperature
Beam Angle
View cart

Shipping, returns & support

Quick product facts

Quick summary
Quick choice: Choose LD4R when you want the most configurable Lotus 4-inch deep-regressed platform: open-plenum construction, premium glare control, multiple trim architectures, finishes and beam options. At a glance:...
Highlights
  • Deep-regressed optical design helps reduce glare and improve visual comfort
  • Configure the exact look with standard
  • Thin Trim

Product identifiers

  • VendorLotus LED Lights
  • SKULD4R-27K-4R-WR-WT
  • GTIN736832281606
  • Product familyRegressed

Technical profile

  • Voltage120V
  • Wattage15
  • Light temperatureMultiple CCT / Dim-to-Warm Options
  • Dimming / controlTRIAC
  • CRI90
  • Mount typeRecessed Mount

Key specifications

Key specifications for Lotus LD4R 4-Inch Deep Regressed LED Downlight – 15W Open Plenum
Voltage 120V
Wattage 15
Light temperature Multiple CCT / Dim-to-Warm Options
Dimming / control TRIAC
CRI 90
Beam type Fixed
Environment Wet Location
Housing ratings IC Rated, Air Tight, Open Plenum
Mount type Recessed Mount
Shape Round
Size 4
Trim style Deep Regressed
Component type Recessed Downlight
Product family Regressed

Verify before ordering

  • Cutout size
  • IC / fire / wet / damp rating
  • Beam angle and CCT
  • Driver and dimming compatibility

Technical fit can depend on site conditions. Contact support if you are replacing an old model or confirming compatibility.

Need help before ordering?

Quick choice: Choose LD4R when you want the most configurable Lotus 4-inch deep-regressed platform: open-plenum construction, premium glare control, multiple trim architectures, finishes and beam options.

At a glance: 4-inch • deep regressed • 15W • open plenum • fixed CCT / 5CCT / Dim-to-Warm options by SKU

  • Best for: architectural residential, commercial and specification-driven projects.
  • Choose this when: trim style, reflector finish, beam angle or open-plenum construction matters.
  • Choose another 4-inch option when: you want a simpler regressed fixture (LL4RR), an adjustable beam (LRG4/Venus), or the lowest-cost ultra-slim general light (LED-S9W).

Use the product options above

Lotus LD4R 15W configuration guide

The selected variant above controls the price, exact SKU, availability and Add to Cart. Use this guide to confirm the installation architecture, finish, colour-temperature behaviour, beam and compatible accessories.

Still comparing the three LD4R families? Use the complete Lotus LD4R buying guide to compare the 15W LD4R, 18W LD4R-HO, corrosion-resistant LD4R-CPL, trim architectures, colour options and beam angles.

15W standard output
Up to 1,500 lumens by CCT
Four architectures
Regular, Thin Trim, Trimless and sloped
Three beams
15°, 30° or 60°
Driver included
120V AC TRIAC dimmable

Practical starting configuration for many residential projects: LD4R 15W, regular visible trim, white outer trim, 3000K or 5-CCT selectable, and the standard 30° beam. Change that starting point only when the ceiling, finish schedule, lighting calculation or desired dimming behaviour requires it.

Ordering rule: The exact Lotus SKU displayed with the selected variant is the ordering contract. Use that finished SKU on the quote, purchase order and order confirmation. The family-level information below does not replace the selected SKU.

Which LD4R model is right for the project?

Model Output Choose it when
LD4R 15W — this page 15W, up to 1,500 lm You need the broadest architecture and finish selection at standard output.
LD4R-HO 18W 18W, up to 1,690 lm The lighting plan requires more output from the same deep-regressed family.
LD4R-CPL 15W or 18W A corrosion-resistant white or black polycarbonate assembly is required.

How to select the correct variant

  1. Choose the architecture: Regular, Thin Trim, Trimless or 5-inch sloped.
  2. Choose the reflector and trim finish: Only use a finish offered within the selected architecture.
  3. Choose the light behaviour: Fixed CCT, Warm Dim or 5-CCT selectable.
  4. Choose the beam: 30° Standard, 15° Spot or 60° Flood.
  5. Verify the SKU above: Use the displayed finished SKU on the quote, purchase order and confirmation.
Warm Dim naming: 32K means Warm Dim 3000K–2000K. It is not fixed 3200K. The 3018K configuration means Warm Dim 3000K–1800K.

Match the architecture to the ceiling

Architecture Installation guidance Compatible rough-in
Regular visible trim 4¼-inch controlled cutout, approximately 3½-inch depth and 4?-inch outside diameter. RIP414, FRP4, MP4 or MP4-2, depending on the construction method.
Thin Trim 3¾-inch controlled cutout. TT means Thin Trim, not Textured Trim. RIP334
Trimless / Invisible Trim Requires architecture-specific preconstruction and ceiling finishing before completion. RIP412 or FRP412
5-inch sloped 5–5½-inch cutout, approximately 6¼-inch outside diameter and approximately 3¼-inch clearance. RIP5 or FRP5. Confirm the exact sloped LD4R configuration and construction method before ordering.

Preconstruction warning: Thin Trim, Trimless and sloped configurations use architecture-specific cutouts and rough-in components. Confirm the finished variant and rough-in plate before drywall, plaster or ceiling cutting begins.

Choose the beam

15° Spot
Narrow distribution for accents, artwork and focused highlights.
30° Standard
Balanced architectural downlighting and the default beam.
60° Flood
Broad distribution for wider, more even coverage.

Lens rule: Finished 15° and 60° SKUs already include the applicable optic. Do not add a second lens unless a replacement optic is specifically required.

For final fixture spacing and delivered-light calculations, use the Lotus photometric or IES files rather than beam angle alone.

Published 15W light output

Fixed CCT and Warm Dim output
2700K 1,380 lm
3000K 1,430 lm
3500K 1,400 lm
4000K 1,500 lm
5000K 1,460 lm
Warm Dim 3000K–2000K 1,130 lm
Warm Dim 3000K–1800K 1,300 lm
5-CCT selectable output
2700K 1,170 lm
3000K 1,240 lm
3500K 1,350 lm
4000K 1,400 lm
5000K 1,420 lm

Driver and accessory guidance

120V vs 120–347V matters: the standard included driver is 120V AC TRIAC dimmable. The 120–347V 0–10V driver is an optional replacement path ordered separately; both control methods are not included in the standard box.

Core family specifications

  • 4¼-inch controlled cutout for regular configurations
  • Approximately 3½-inch fixture depth
  • Approximately 4?-inch outside diameter
  • 15W standard-output LED module
  • Up to 1,500 lumens depending on CCT selection
  • 90+ CRI
  • 30° standard beam with configured 15° and 60° options
  • Type IC and airtight
  • Wet-location rated
  • Open-plenum rated
  • IP54
  • cULus certified
  • Published operating range: ?40°C to +40°C
  • Projected life: 50,000 hours to 70% light output
  • No separate traditional recessed housing required

Architecture-specific dimensions, cutouts and rough-in requirements apply to Thin Trim, Trimless and sloped configurations. Confirm the exact selected SKU before cutting or finishing the ceiling.

Documents and project support

Frequently asked questions

Does 32K mean fixed 3200K?

No. In this product family, 32K means Warm Dim 3000K–2000K. It is not a fixed 3200K colour temperature.

What does TT mean?

TT means Thin Trim, not Textured Trim. It uses a 3¾-inch controlled cutout and the dedicated RIP334 rough-in plate.

Do I need another lens for a 15° or 60° variant?

No. The finished 15° and 60° SKUs already include the applicable optic. A separate lens is needed only when an existing optic is being replaced.

Is the included driver 0–10V?

No. The included driver is 120V AC TRIAC dimmable. LLL-LD1535TR is the optional driver for compatible 120–347V AC and 0–10V projects.

Which rough-in plate does the LD4R use?

The correct rough-in plate depends on the selected architecture. Regular visible-trim configurations may use RIP414, FRP4, MP4 or MP4-2 depending on the construction method. Thin Trim uses RIP334, Trimless uses RIP412 or FRP412, and the sloped architecture uses a separate 5-inch rough-in path. Confirm the selected variant before ordering.

Should I choose LD4R 15W or LD4R-HO 18W?

Start with the 15W LD4R for typical residential ceiling heights and standard-output layouts. Choose the 18W LD4R-HO when the lighting calculation, mounting height or task requirement justifies the additional output. More lumens are not automatically better.

Configure the exact LD4R 15W variant above

For many residential projects, begin with regular visible trim, a white outer trim, 3000K or 5-CCT selectable, and the standard 30° beam. Select Thin Trim, Trimless, sloped, Warm Dim, 15° or 60° only when the project requires that specific result.

Need to compare families first? Open the complete Lotus LD4R buying guide.